SPARES2GO Glass Opti-Myst Heater Disk Transducer RM-1220 Compatible with Dimplex Electric Wall Fire

To the offer

Price comparison

Price trend

Product description

  • Fits models Burbank BBK20 (Series A - D), BBK20 (Series E) -- Danville DNV20CH (Series A - Onward ), DNV20AB (Series A - C), DNV20BL (Series A - Onwards), DNV20BR (Series A - C) -- Moorefield MFD20 (Series A) -- Oakhurst OKT20 (Series A) -- Redway RDY20 (Series A - D), RDY20 (Series E) -- Sacramento SCR20 (Series A) -- Tahoe TAH20 (Series A), TAH20 (Series E)
  • and models Westbrook WBK20 (Series A) -- Whitmore WMR20 (Series A) -- Alameda ALM20 (Series A) -- Auberry AUB20 (Series A) -- Cassette CAS600, CAS400NHLL, CAS400HLL, CAS600NH -- Remote Control RTOPCS20, RTOPW20, RTOPI20BR, RTOPI20CH -- Silverton SVT20 (Series A)
  • Please note replacement of your transducer may be required if no mist is being produced, or if the fire cuts off after 30 seconds. There are several other components which may also contribute to lack of mist, or premature cutting out - such as a faulty sump fan unit, a build-up of calcium deposits, insufficient incorrect water level in the tank, faulty lamps, damage to the mist nozzle or incorrect fitting of the transducer.
  • Therefore, repairs should always be carried out by a suitably qualified or competent engineer. The approximate life-span of this transducer is 1000 hours. Replacement discs and or removal tool must be bought separately. Spare discs not included. Premium quality, fully compatible replacement spare part.
  • This product is designed to be compatible with the specified brand(s) and is not the original part. The name, model names and any part numbers of the original manufacturer(s) have been used for reference purposes only and are in no way associated with the original parts or manufacturer.